Any specified components intended for use with an HFC refrigerant or refrigerant blend containing an HFC is for servicing existing equipment only, unless the end use is not covered by the Environmental Protection Agency (EPA) Transition Rule. Before using the specified component with a regulated substance, please check the Environmental Protection Agency (EPA) rules at the EPA website.
More information about the suitable refrigerants for each product, please access our Product-Selector Software.
To understand what refrigerant the specified component is intended for use with, please see the tables below:
Compressor EM
Standard generation
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
Standard mechanical kit
Non standard
Compressor capacity in BTU/H - 60Hz - Ashrae
Check point divided by 10
Standard efficiency (LBP)
Intermediate efficiency (LBP)
Improved efficiency first generation (LBP)
Improved efficiency second generation (LBP)
Standard efficiency (L/M/HBP)
Standard efficiency (HBP)
Standard efficiency (M/HBP)
Blends
R600a
R134a; R513A and R450A
R290
PTC + Run Cap (optional)
Relay
PTC + Run Cap (mandatory)
PTC + Run Cap + Start Cap
PTC + Run Cap + Start Cap (optional)
Relay + Start Cap (mandatory)
Standard generation
Improved efficiency first generation
Improved efficiency second generation (for commercial refrigeration)
Standard mechanical kit
Non standard
Approximate capacity in Btu/h - 60Hz
ASHRAE - checkpoint divided by 10
Blends
R134a; R513A and R450A
R290
R1234yf
L / MBP
L / M / HBP
LST (Low Starting Torque)
HST (High Starting Torque)
Commercial EM / NE / NT / NJ
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
LBP / HST
L- MBP / LST
L-MBP / HST
M-HBP / LST
M-HBP / HST
M-HBP / HST
The first digit is the number of zeros that must be added to the last two digits to obtain the cooling capacity (approx.) in kcal/h at 50 Hz.
E.g.: 144= 440 kcal/h at 50 Hz.
R404A; R448A; R449A; R452A and R407C
R454A; R454C
R454A and R454C 3 phase
R290; R454C
R134a; R513A and R450A
R600a
IPR valve
Available for some models
VEG
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
in cm²
R134a
R600a
R290
R1234yf
Extended evaporation range until 23 F (L/MBP)
Standard evaporation range
VEM / FMF / VNE
First generation
Second generation
Third generation
Fourth generation
LBP / LST
LBP / HST
L-MBP / LST
L-MBP / HST
M-HBP / LST
M-HBP / HST
in cm²
R290
R134a
R123yf
R404A
Condensing unit
EM
Standard generation
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
Standard mechanical kit
Non standard
Compressor capacity in BTU/H - 60Hz - Ashrae
Check point divided by 10
Standard efficiency (LBP)
Intermediate efficiency (LBP)
Improved efficiency first generation (LBP)
Improved efficiency second generation (LBP)
Standard efficiency (L/M/HBP)
Standard efficiency (HBP)
Standard efficiency (M/HBP)
Blends
R600a
R134a; R513A and R450A
R290
PTC + Run Cap (optional)
Relay
PTC + Run Cap (mandatory)
PTC + Run Cap + Start Cap
PTC + Run Cap + Start Cap (optional)
Relay + Start Cap (mandatory)
Condensing Unit
F
Improved efficiency first generation
Improved efficiency second generation (for commercial refrigeration)
Standard mechanical kit
Non standard
Approximate capacity in Btu/h - 60Hz
ASHRAE - checkpoint divided by 10
Blends
R134a; R513A and R450A
R290
R1234yf
L/MBP
L/M/HBP
LST (Low Starting Torque)
HST (High Starting Torque)
Condensing unit
Commercial EM / NE/ NT / NJ
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
LBP / HST
L-MBP / LST
L-MBP / HST
M-HBP / LST
M-HBP / HST
M-HBP / HST
The first digit is the number of zeros that must be added to the last two digits to obtain the cooling capacity (approx.) in kcal/h at 50 Hz.
E.g.: 144= 440 kcal/h at 50 Hz.
R404A; R448A; R449A; R452A and R407C
R454A; R454C
R454A; R454C 3 phase
R290; R454C
R134a; R513A and R450A
R600a
IPR valve
Available for some models
Condensing unit
VEG
First generation
Second generation
Third generation
Fourth generation
Fifth generation
Sixth generation
in cm²
R134a
R600a
R200
R1234yf
Extended evaporation range until 23 F (L/MBP)
Standard evaporation range
Indoor
EM / F / NE / NT / NJ
0150 : 150HP
0025 : 25HP
LBP
MBP
L / MBP
R404A
R454A;R454C
R134a, R513A and R450A
R290
220W/1/50 - 60Hz
280-230V/1/60Hz
115 - 127V/1/60HzG -115V/1/60Hz
Bare
Finned condenser
Water cooled
No components
Version
Version
Version
Customized
No components
Version
Version
Version
Condensing Unit
Product platform
ES platform
EM platform
F platform
EH platform
NE platform
NT platform
NJ platform
Platform rating
Based on ARILBP or
ARIMBP performance
LBP
MBP
L/MBP
M/HBP
R404A/R448A/R449A
R134a/R513A
R290
R454A; R454C
R454A; R454C 3 phase
220V/1ph/50-60Hz
208-230V/1ph/60Hz
115-127V/1ph/60Hz
115V/1ph/60Hz
220-240V/1ph/50Hz
Finned air cooled
Water cooled
Helical
CDU type - XX
Bare - 44
Plus - 24
Custom #1 - 03
Small EDP
Medium EDP
Condensing Unit
Product platform
FMS platform
FMX platform
VES platform
VEM platform
FMF platform
VNE platform
VNT platform
Platform rating
Based on ARILBP or
ARIMBP performance
LBP
MBP
L/MBP
M/HBP
R404A/R448A/R449A
R134a/R513A
R290
R454A; R454C
R454A; R454C 3 phase
220V/1ph/50-60Hz
208-230V/1ph/60Hz
115-127V/1ph/60Hz
115V/1ph/60Hz
220-240V/1ph/50Hz
Finned air cooled
Water cooled
Helical
CDU type - XX
Bare - 44
Plus - 24
Custom #1 - 03
Small EDP
Medium EDP
Sealed Unit
FMF / F
Standard efficiency
Top efficiency
LBP / LST
LBP / HST
L-MBP / LST
L-MBP / HST
M-HBP / LST
M-HBP / HST
in cm².
R290
R134a
R123yf
R404A
R454A; R454C
R454A; R454C 3 phase