Any specified components intended for use with an HFC refrigerant or refrigerant blend containing an HFC is for servicing existing equipment only, unless the end use is not covered by the Environmental Protection Agency (EPA) Transition Rule. Before using the specified component with a regulated substance, please check the Environmental Protection Agency (EPA) rules at the EPA website.

More information about the suitable refrigerants for each product, please access our Product-Selector Software.

To understand what refrigerant the specified component is intended for use with, please see the tables below:



Compressors Families

EM

EM I S 70 H H R
Compressor family
EM

Compressor EM

I
Efficiency level

Standard generation

I

First generation

T

Second generation

U

Third generation

Y

Fourth generation

Z

Fifth generation

X

Sixth generation

S
Mechanical kit
S

Standard mechanical kit

Non standard

70

Compressor capacity in BTU/H - 60Hz - Ashrae

Check point divided by 10

H
Application
N

Standard efficiency (LBP)

J

Intermediate efficiency (LBP)

E

Improved efficiency first generation (LBP)

S

Improved efficiency second generation (LBP)

H

Standard efficiency (L/M/HBP)

D

Standard efficiency (HBP)

B

Standard efficiency (M/HBP)

H
Refrigerant Code

Blends

C

R600a

H

R134a; R513A and R450A

U

R290

R
Electrical equipment
LST: P

PTC + Run Cap (optional)

R

Relay

C

PTC + Run Cap (mandatory)

S

PTC + Run Cap + Start Cap

V

PTC + Run Cap + Start Cap (optional)

HST: X

Relay + Start Cap (mandatory)

F

F U S 130 H A X
F
Compressor family
F

U
Standard efficiency

Standard generation

I

Improved efficiency first generation

U

Improved efficiency second generation (for commercial refrigeration)

S
Mechanical kit
S

Standard mechanical kit

Non standard

130

Approximate capacity in Btu/h - 60Hz

ASHRAE - checkpoint divided by 10

H
Refrigerant Code

Blends

H

R134a; R513A and R450A

U

R290

L

R1234yf

A
Application
A

L / MBP

B

L / M / HBP

X
Starting characteristic
K

LST (Low Starting Torque)

X

HST (High Starting Torque)

Commercial EM / NE / NT / NJ

Family U 6 224 Z V
Family
Compressor family

Commercial EM / NE / NT / NJ

U
Efficiency level

First generation

K

Second generation

T

Third generation

U

Fourth generation

Y

Fifth generation

X

Sixth generation

Z
Application code
2

LBP / HST

3

L- MBP / LST

4

L-MBP / HST

5

M-HBP / LST

6

M-HBP / HST

9

M-HBP / HST

224

The first digit is the number of zeros that must be added to the last two digits to obtain the cooling capacity (approx.) in kcal/h at 50 Hz.

E.g.: 144= 440 kcal/h at 50 Hz.

Z
Refrigerant Code
GK/GJ

R404A; R448A; R449A; R452A and R407C

GL

R454A; R454C

GM

R454A and R454C 3 phase

U

R290; R454C

Z

R134a; R513A and R450A

Y

R600a

V

IPR valve

Available for some models

VEG

VEG T 8 and 11 H B
Compressors Families

VEG

T
Product generation
Y

First generation

T

Second generation

Z

Third generation

X

Fourth generation

C

Fifth generation

D

Sixth generation

8 and 11
Displacement

in cm²

H
Refrigerant Code
H

R134a

C

R600a

U

R290

L

R1234yf

B
Evaporation range
B

Extended evaporation range until 23 F (L/MBP)

Standard evaporation range

VEM / FMF / VNE

FAMILY T 4 13 U
Compressor family

VEM / FMF / VNE

T
Efficiency level
K

First generation

U

Second generation

T

Third generation

D

Fourth generation

4
Application and torque
1

LBP / LST

2

LBP / HST

3

L-MBP / LST

4

L-MBP / HST

5

M-HBP / LST

6

M-HBP / HST

13
Displacement

in cm²

U
Refrigerant Code
U

R290

D

R134a

E

R123yf

GK

R404A

Condensing units

First Generation

UEM

U EM I S 70 H H R
Product platform
U

Condensing unit

Compressor family

EM

I
Efficiency level

Standard generation

I

First generation

T

Second generation

U

Third generation

Y

Fourth generation

Z

Fifth generation

X

Sixth generation

H
Mechanical kit
S

Standard mechanical kit

Non standard

70

Compressor capacity in BTU/H - 60Hz - Ashrae

Check point divided by 10

H
Application
N

Standard efficiency (LBP)

J

Intermediate efficiency (LBP)

E

Improved efficiency first generation (LBP)

S

Improved efficiency second generation (LBP)

H

Standard efficiency (L/M/HBP)

D

Standard efficiency (HBP)

B

Standard efficiency (M/HBP)

H
Refrigerant Code

Blends

C

R600a

H

R134a; R513A and R450A

U

R290

R
Electrical equipment
LST: P

PTC + Run Cap (optional)

R

Relay

C

PTC + Run Cap (mandatory)

S

PTC + Run Cap + Start Cap

V

PTC + Run Cap + Start Cap (optional)

HST: X

Relay + Start Cap (mandatory)

UF

U F U S 130 H A X
Product platform
U

Condensing Unit

Compressor Family

F

U
Standard efficiency
I

Improved efficiency first generation

U

Improved efficiency second generation (for commercial refrigeration)

S
Mechanical kit
S

Standard mechanical kit

Non standard

130

Approximate capacity in Btu/h - 60Hz

ASHRAE - checkpoint divided by 10

H
Refrigerant Code

Blends

H

R134a; R513A and R450A

U

R290

L

R1234yf

A
Application
A

L/MBP

B

L/M/HBP

X
Starting Characteristic
K

LST (Low Starting Torque)

X

HST (High Starting Torque)

Commercial UEM / UNE / UNT / UNJ

U Family U 6 224 Z V
U
Product platform
U

Condensing unit

Family
Compressor families

Commercial EM / NE/ NT / NJ

U
Efficiency level

First generation

K

Second generation

T

Third generation

U

Fourth generation

Y

Fifth generation

X

Sixth generation

6
Application code
2

LBP / HST

3

L-MBP / LST

4

L-MBP / HST

5

M-HBP / LST

6

M-HBP / HST

9

M-HBP / HST

224

The first digit is the number of zeros that must be added to the last two digits to obtain the cooling capacity (approx.) in kcal/h at 50 Hz.

E.g.: 144= 440 kcal/h at 50 Hz.

Z
Refrigerant Code
GK/GJ

R404A; R448A; R449A; R452A and R407C

GL

R454A; R454C

GM

R454A; R454C 3 phase

U

R290; R454C

Z

R134a; R513A and R450A

Y

R600a

V

IPR valve

Available for some models

UVEG

U VEG T 8 and 11 H B
Product platform
U

Condensing unit

Compressor Family

VEG

T
Product generation
Y

First generation

T

Second generation

Z

Third generation

X

Fourth generation

C

Fifth generation

D

Sixth generation

8 and 11
Displacement

in cm²

H
Refrigerant Code
H

R134a

C

R600a

U

R200

L

R1234yf

B
Evaporation range
B

Extended evaporation range until 23 F (L/MBP)

Standard evaporation range

Second Generation

UEM / UF / UNE / UNT / UNJ

U FAMILY 0150 L G D A 1 1 A
U
Use
U

Indoor

Compressors Families

EM / F / NE / NT / NJ

0150
HP example

0150 : 150HP

0025 : 25HP

L
Application
L

LBP

M

MBP

X

L / MBP

GK
Refrigerant Code
GK

R404A

GL/GM

R454A;R454C

Z/H

R134a, R513A and R450A

U

R290

D
Input voltage

220W/1/50 - 60Hz

D

280-230V/1/60Hz

E

115 - 127V/1/60HzG -115V/1/60Hz

Bare

A
Condenser
A

Finned condenser

W

Water cooled

1
Mechanical Component
O

No components

1

Version

2

Version

3

Version

9

Customized

1
Electrical component
O

No components

2

Version

3

Version

A

Version

Mechanical component
1
2
1
2
9
Electrical component
1
2
1
2
9
Condensing unit version
Bare
Plus
Ultimate
Ultimate compact
Customized

Evaporative Drain Pan

UES / UEM / UF / UEH / UNE / UNT / UNJ

U FAMILY 0020 L U E A X X 8
U
Product platform
U

Condensing Unit

Compressors families

Product platform

ES

ES platform

EM

EM platform

F

F platform

EH

EH platform

NE

NE platform

NT

NT platform

NJ

NJ platform

0020

Platform rating

Based on ARILBP or

ARIMBP performance

L
Application
L

LBP

M

MBP

X

L/MBP

Y

M/HBP

U
Refrigerant Code
G

R404A/R448A/R449A

Z

R134a/R513A

U

R290

GL

R454A; R454C

GM

R454A; R454C 3 phase

E
Input voltage
B

220V/1ph/50-60Hz

D

208-230V/1ph/60Hz

E

115-127V/1ph/60Hz

G

115V/1ph/60Hz

A

220-240V/1ph/50Hz

A
Condenser
A

Finned air cooled

W

Water cooled

H

Helical

XX

CDU type - XX

Bare - 44

Plus - 24

Custom #1 - 03

8
Baseplate
S

Small EDP

M

Medium EDP

UFMS / UFMX / UVES / UVEM / UFMF / UVNE / UVNT

U FAMILY 0020 L U E A X X 8
U
Product platform
U

Condensing Unit

Compressors families

Product platform

FMS

FMS platform

FMX

FMX platform

VES

VES platform

VEM

VEM platform

FMF

FMF platform

VNE

VNE platform

VNT

VNT platform

0020

Platform rating

Based on ARILBP or

ARIMBP performance

L
Application
L

LBP

M

MBP

X

L/MBP

Y

M/HBP

U
Refrigerant Code
G

R404A/R448A/R449A

Z

R134a/R513A

U

R290

GL

R454A; R454C

GM

R454A; R454C 3 phase

E
Input voltage
B

220V/1ph/50-60Hz

D

208-230V/1ph/60Hz

E

115-127V/1ph/60Hz

G

115V/1ph/60Hz

A

220-240V/1ph/50Hz

A
Condenser
A

Finned air cooled

W

Water cooled

H

Helical

XX

CDU type - XX

Bare - 44

Plus - 24

Custom #1 - 03

8
Baseplate
S

Small EDP

M

Medium EDP

Sealed Units

SFMF / SF

S Family T 4 13 U
Product Platform
S

Sealed Unit

Compressors Families

FMF / F

T
Efficiency level
T

Standard efficiency

D

Top  efficiency

4
Application and torque
1

LBP / LST

2

LBP / HST

3

L-MBP / LST

4

L-MBP / HST

5

M-HBP / LST

6

M-HBP / HST

13
Displacement

in cm².

U
Refrigerant Code
U

R290

Z

R134a

L

R123yf

GK

R404A

GL

R454A; R454C

GM

R454A; R454C 3 phase